<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-03 16-54-07
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 18327 0,1255
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,1 dBr 2,79 dBr 3,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 0,1255 Acquired: 2026.09.03 16.53.04 Total samples: 18327 Equivalent time: 0:15:16 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,3 dBr MIN: 2,1 dBr AVE: 2,79 dBr % above 12,2 dBr: 0,0 Last value: 2,4 dBr (2026.09.03 16.53.03) 16.40 16.42 16.44 16.46 16.48 16.50 16.52 -1 0 1 2 3 4 Pm [dBr]